Bapsule EV Outlets
An EV Outlet combines the approved dock schedule, the selected pods and the site infrastructure — bays, electrical room, canopy, integration and acceptance — under one project contract. Three archetypes organise the first conversation; every outlet is engineered for its site.

Site archetypes
Planning references from the outlet tier catalogue and the site design brief. They organise a first conversation; they are not package specifications, do not establish that every plot in a band will fit, and are recalculated for the site, the selected equipment and the utility connection.
Existing property or urban charging
A compact charging site on an existing property: a few bays, one DC unit, AC docks, signage, lighting and CCTV, with a pod as an option.
Corridor, campus or fleet-adjacent site
A corridor or campus site with a 120 kW dual-gun DC unit, AC docks, waiting, washroom and café amenities and solar options.
Destination or highway amenity site
A destination site with higher-power DC charging, more AC docks, lounge, food, retail and sanitation pods and engineered energy options — planned per project.
Scope
The same boundaries apply to every archetype. The quotation lists the items in each column for the specific site.
Configuration comparison
| Planning field | StarterExisting property or urban charging | GrowthCorridor, campus or fleet-adjacent site | Highway HubDestination or highway amenity site |
|---|---|---|---|
| Reference DC mix | One dual-outlet DC unit (the source lists 50 kW; Bapsule evaluates 30 or 60 kW floor units) | One 120 kW dual-outlet DC unit (Bapsule BPX-DC-120-F candidate) | One 180 kW dual-outlet DC unit — an engineered, enquiry configuration in the Bapsule Dock range |
| Reference AC mix | 2 × 22 kW Type 2 docks | 2 × 22 kW Type 2 docks | 2 – 4 × 22 kW Type 2 docks |
| Reference parking | 4 bays (2 DC + 2 AC), one accessible | 4 – 6 bays, one accessible | 6 – 8 bays plus selected amenities; bus or light-commercial bay option |
| Plot band | 2,000 – 4,400 sq ft (about 186 – 410 m²) | 4,356 – 8,712 sq ft (about 0.10 – 0.20 acre) | 10,000 – 32,670 sq ft (about 0.23 – 0.75 acre) |
| Reference demand | 100 kVA sanctioned load, verified against the final dock schedule | 200 kVA sanctioned load, verified against the final dock schedule | 320 – 500 kVA, typically a high-tension connection, verified against the final schedule |
| Amenity selection | Signage, lighting, CCTV; a selected Pod as an option | Waiting area, washroom and café pods; solar options | Lounge, food and beverage, retail and sanitation pods; engineered energy options |
| Pricing | Request a project quotation | Request a project quotation | Request a project quotation |
The sum of the equipment nameplates on site.
The charging power that can actually be delivered after power sharing, limits and derating.
The upstream utility input, including losses and auxiliary loads, that the sanctioned load must cover.
Physical bays can exceed the number of vehicles charging at the same time.
Reference mixes come from the outlet tier catalogue and the site design brief. The Starter DC unit is listed there as 50 kW, which is not a priced Bapsule configuration — 30 and 60 kW floor units are evaluated instead; 180 kW for the Highway Hub is an engineered enquiry configuration.
Amenity options
Each amenity in an outlet is a Bapsule Pod type with its own shell, fit-out and utility scope. Energy options are engineered systems listed separately.
BPX-CAFE
A factory-built café shell with counter and fixed glazing that sits beside charging bays or on any forecourt setback.
BPX-SEC
A guard cabin and surveillance node with CCTV, access-control and backup-power options in a weather-sealed shell.
BPX-SAN
A self-contained sanitation block with water storage, treatment options and accessible units for sites, transit hubs and events.
BPX-RTL
A glazed storefront pod for transit hubs, high streets and forecourts, with retail fit-out, climate and security options.
BPX-RE
Solar generation with optional wind and storage on a relocatable chassis — captive supply or grid-connected, engineered per site.
BPX-OFC
A site office, sales suite or meeting pod with insulation, acoustic lining, climate control and connectivity.
BPX-BESS
Containerised battery storage from 100 kWh upwards for peak shaving, solar time-shift, charging buffers and backup — designed per installation.
Site readiness
Planning minimums from the site design brief; verified against the measured plot, utility position and local approvals before drawings are frozen.
| Car DC bay | 3.0 × 5.5 m (minimum clear 2.7 × 5.0 m); charger side widened for cable handling and door swing |
|---|---|
| Car AC bay | 2.7 × 5.0 m (minimum clear 2.5 × 5.0 m) |
| Accessible bay | 3.6 × 5.0 m, at least one per site, level and adjacent to the charger |
| Bus or light-commercial bay | 4.0 × 14.0 m, pull-through preferred, heavy-duty pavement — Highway Hub option |
| Cabinet to cabinet | 0.8 m for ventilation and side service access |
| Charger front to vehicle | 1.0 – 1.2 m operator zone |
| Charger rear to wall or column | 0.6 m for the service door and conduit entry |
| Cable reach | Verified with the supplied cable: the design brief assumes 5 m with about 4 m reach; the Dock catalogue states 4 m cables |
| Drive aisle | 6.0 – 7.0 m two-way · 3.5 – 4.0 m one-way |
| Entry and exit | 6.0 m gate, or 2 × 3.5 m with separate in and out on busy sites |
| Turning radius | 6.0 m inner kerb for cars · 12.5 m swept path for buses |
| Canopy clear height | 5.0 m for cars · 5.5 m for buses |
| Fire-tender access | 6.0 m clear perimeter route |
| Electrical / LT room | 3.0 × 4.0 m · 3.5 × 5.0 m · 4.0 × 6.0 m by archetype |
| Transformer yard | 3 × 3 m (Growth) · 4 × 4 m (Highway Hub), fenced with 3 m setback, where the connection requires it |
| Storage enclosure | 3 × 3 m ventilated, separated enclosure when storage is in scope (Highway Hub) |
Factory lead time, transport, site works and approvals, installation and commissioning are programmed separately.
Questions
No. The three archetypes organise a first conversation. Each outlet is engineered for its site and quoted as one project contract with a reconciled bill of quantities after a site assessment.
Bapsule EV Docks from the catalogue. Starter sites are evaluated around 30 or 60 kW DC floor units with 22 kW AC docks; Growth sites around the 120 kW dual-gun unit; higher-power hub options are engineered to order. Every mix is recalculated for demand, bays and the utility connection.
A plot band is not a fit. Bays, aisles, turning, clearances, the electrical room and the connection are checked against the measured plot during the site assessment.
A defined provision — structure, space, cabling route or interface — not installed equipment. Solar arrays and storage systems are engineered, listed and quoted separately.
The customer holds the connection and the approvals; Bapsule prepares the design basis, load schedule and documentation and coordinates the interfaces where contracted.
Handover includes as-built records, manuals, test results, commissioning settings, a warranty matrix, a maintenance plan and a defined support route. Operation, tariffs, staffing and licences stay with the owner unless separately contracted.
Share the plot, the connection and the intended use. We respond with the assessment steps and, after the assessment, a reconciled bill of quantities.