DC Floor · CCS2 · 60 · 80 · 120 kW catalogue (180 – 360 kW on enquiry)
Two CCS2 guns on one floor cabinet, sharing power between two vehicles.

Overview
The dual-gun DC floor charger connects two vehicles to one 675 × 2012 × 690 mm cabinet and shares the cabinet rating between them: two guns do not mean two full-rated outputs at once. The standard family covers 60 – 240 kW at 100 – 750 V DC with up to 160 A per gun; a high-power version covers 120 – 360 kW at 200 – 1000 V DC and 200 A. The 60, 80 and 120 kW units are catalogue configurations; 180, 240 and 360 kW are engineered enquiry configurations.
Catalogue applications
Configurations
Each configuration has a model code and a source-stated specification and is quoted per configuration.
BPX-DC-60-F
Highway hubs
BPX-DC-80-F
Highway hubs
BPX-DC-120-F
Highway hubs
Enquiry configurations
Specification, electrical envelope, tests and commercial scope are approved per project before supply.
Specification
Values are catalogue statements for the family. Items shown as “Confirmed at quotation” differ between catalogue pages or are not supplied, and are confirmed per model and revision.
| Family power range | Confirmed at quotation |
|---|---|
| Phase / wire | 3-phase — L1, L2, L3, N and PE, 5-wire AC system |
| THD & power factor | 5 % at nominal voltage · 0.99 at full load |
| Output port | CCS2 — combined charging system (GB/T and CHAdeMO optional) |
| Number of connectors | 2 |
| Efficiency | Confirmed at quotation |
| Electrical protection | Over-current, under-voltage, over-voltage, surge, short-circuit, over-temperature, earth leakage, 30 mA ground fault |
| Charging protocol | OCPP 1.6J |
| EVSE ↔ CMS | Ethernet, 4G (optional) |
| Display | 7″ LCD display |
| Emergency stop | Red mushroom-headed emergency stop button |
| Authentication | RFID, QR code or operator app; offline authentication available |
| Billing & payment | Session billing, payments, monitoring and alerts are functions of the connected charging management system; confirmed per deployment |
| Operating temperature | Confirmed at quotation |
| Humidity & altitude | < 95 % RH non-condensing · up to 2,000 m |
| Ingress protection | Confirmed at quotation |
| Impact protection | IK10 (cabinet) · IK08 (touchscreen) |
| Cooling / mounting | Natural cooling · floor mounted |
| Dimensions | 675 × 2012 × 690 mm (W × H × D) |
| Weight by capacity | 130 kg (60 kW) · 190 kg (120 kW) · 290 kg (180 kW) · 340 kg (240 kW) |
| Cable length | 4.0 m |
Installation and connectivity
Authentication, billing and monitoring are functions of the connected charging management system; each dock-and-CMS pairing is demonstrated at commissioning.
Scope
Downloads: a Bapsule-branded datasheet for this family is issued with the quotation; no catalogue file is offered for download until approved.
Related and enquiry
Pricing
Quoted per configuration
Dock quotations state the model and revision, connectors and cable, mounting, controls, protection and the communication option. Pedestal or plinth, upstream protection, cable runs, utility work, CMS subscriptions, payment integration and commissioning are listed separately where required.